TM 5-3825-270-23&P
0099
WEATHERPACK CONNECTOR REPAIR - Continued
CAUTION
Strip wire after placing it through seal. Failure to comply may cause damage to equipment.
6.
Strip end of wire (Figure 7, Item 8), leaving 1/4 in. (6 mm) of bare wire.
7
6
8
9
Figure 7. Wire Seal With Insulation.
7.
Insert terminal (Figure 7, Item 6) in locating hole of weatherpack crimper (Figure 7, Item 9) using proper hole
according to the gauge of wire (Figure 7, Item 8).
8.
Slide wire seal (Figure 7, Item 7) down to end of insulation on wire (Figure 7, Item 8).
NOTE
Wire and seal should be positioned so larger wings of terminal will crimp around seal,
and smaller wings will crimp around exposed bare wire.
Ensure all strands of wire are inside terminal when installing.
9.
Position wire (Figure 7, Item 8) on terminal (Figure 7, Item 6).
10.
Press handles of weatherpack crimper (Figure 8, Item 9) together until ratchet releases and crimp is complete.
0099-6