Figure 13. Joint With Solder.
Figure 17. Double Joint With Solder and Heatshrink.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  571    572    573    574    575  576  577    578    579    580    581  
img
.
TM 5-3825-270-23&P
0099
WIRE SOLDER REPAIR - Continued
4
5
6
5
4
7
7
Figure 15. Splice Double Joint Soldering.
8.
Cut section of wire (Figure 15, Item 6) 2 in. (50 mm) longer than distance measured in Step 7.
9.
Remove 3/4 in. (19 mm) of insulation (Figure 15, Item 7) from both ends of wire (Figure 15, Item 6).
10.
Slide two 3 in. (76 mm) pieces of heatshrink tubing (Figure 15, Item 5) over ends of wires (Figure 15, Item 4).
WARNING
Allow solder to cool prior to handling. Failure to comply may result in injury or death to
personnel.
NOTE
Ensure solder flows evenly on both ends of wire.
11.
Twist bare ends of wires (Figure 16, Item 4) and (Figure 16, Item 6) together and solder.
5
4
APPLY
6
SOLDER
4
5
Figure 16. Double Joint With Soldering.
12.
Slide heatshrink tubing (Figure 17, Item 5) over solder joint.
0099-11