Figure 15. Splice Double Joint Soldering.
Figure 18. Jumper Wire Fabrication.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  572    573    574    575    576  577  578    579    580    581    582  
img
.
TM 5-3825-270-23&P
0099
WIRE SOLDER REPAIR - Continued
4
5
6
5
4
Figure 17. Double Joint With Solder and Heatshrink.
WARNING
Never use open flame to apply heat to heatshrink tubing. Allow heatshrink tubing to cool prior
to handling. Failure to comply may result in injury or death to personnel.
CAUTION
Do not overheat tubing. Failure to comply may cause damage to wire.
NOTE
Ensure solder joint is centered in heatshrink tubing.
13.
Apply heat to heatshrink tubing (Figure 17, Item 5). Allow tubing to shrink until tight on solder joint and insulation
of wires (Figure 17, Item 4) and (Figure 17, Item 6).
14.
Repeat Steps 11 thru 13 for other soldered joint.
END OF TASK
JUMPER WIRE FABRICATION
Strip approximately 1 in. (25 mm) off each end of wire (Figure 18, Item 1).
0099-12