• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 3. Spade Connector Repair.
Figure 7. Wire Seal With Insulation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  565    566    567    568    569  570  571    572    573    574    575  
img
.
TM 5-3825-270-23&P
0099
WEATHERPACK CONNECTOR REPAIR - Continued
WARNING
Tip of removal tool is very sharp. Use care when using removal tool. Failure to comply may
result in injury or death to personnel.
2.
Insert terminal remover (Figure 5, Item 5) into cavity (Figure 5, Item 4) on connector (Figure 5, Item 1), and
(Figure 5, Item 3) until seated.
5
4
3
1
2
6
7
8
Figure 5. Connector Breakdown.
3.
Pull wire (Figure 5, Item 8), terminal (Figure 5, Item 6), and wire seal (Figure 5, Item 7) back through connectors
(Figure 5, Item 1), and (Figure 5, Item 3) and remove terminal remover (Figure 5, Item 5).
NOTE
Make cut directly behind damaged terminal.
4.
Cut and remove terminal (Figure 5, Item 6) and wire seal (Figure 5, Item 7) from wire (Figure 5, Item 8).
5.
Insert 1 in. (25 mm) of wire (Figure 6, Item 8) through wire seal (Figure 6, Item 7).
8
7
Figure 6. Wire With Seal.
0099-5


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.