BATTERY VOLTAGE GAUGE DOES NOT OPERATE OR READS HIGH
Figure 2. Control Panel Faceplate Screws - Step 2.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  145    146    147    148    149  150  151    152    153    154    155  
img
. .
TM 5-3825-270-23&P
0028
ENGINE OFF / BATTERY
DRAIN INDICATOR
Figure 1. Engine Off/Battery Drain Indicator - Step 1.
CONDITION/INDICATION
Does ENGINE OFF/BATTERY DRAIN light illuminate?
DECISION
No - Go to No Power To Control Panel. (WP 0027)
Yes - Go to step 2. (Step 2 - Are 22 to 28 VDC present at BATTERY VOLTAGE gauge harness connector, pin
6?)
STEP 2
Are 22 to 28 VDC present at BATTERY VOLTAGE gauge harness connector, pin 6?
WARNING
Remove all jewelry such as rings, ID tags, bracelets, etc., prior to working on or around
vehicle. Jewelry and tools can catch on equipment, contact positive electrical circuits, and
cause a direct short, severe burns, or electrical shock. Failure to comply may result in injury
or death to personnel.
1.
Push in EMERGENCY STOP switch to off position. (TM 5-3825-270-10)
2.
Remove six control panel faceplate screws.