Figure 11. 15-amp Circuit Breaker Terminal 1 - Step 9.
BATTERY VOLTAGE GAUGE DOES NOT OPERATE OR READS HIGH

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  143    144    145    146    147  148  149    150    151    152    153  
img
. .
TM 5-3825-270-23&P
0027
4.
Note multimeter reading.
CONDITION/INDICATION
Are 22 to 28 VDC present at 15-amp circuit breaker terminal 2?
DECISION
No - Replace 15-amp circuit breaker. (WP 0078) Verify problem is solved. (Step 11 - Does control panel have
power?)
Yes - Repair or replace red wire from 15-amp circuit breaker, terminal 2 to EMERGENCY STOP switch.
(WP 0099) Verify problem is solved. (Step 11 - Does control panel have power?)
STEP 11
Does control panel have power?
Attempt to apply power to control panel. (TM 5-3825-270-10)
CONDITION/INDICATION
Does control panel have power?
DECISION
No - If the problem still exists, it is possible that another fault exists or that another troubleshooting procedure
applies. If this was the first time through the task, restart the same symptom troubleshooting fault task.
Yes - Your original problem has been resolved.
END OF WORK PACKAGE
0027-11/12 blank