Figure 10. Negative Battery Terminal - Step 8.
NO POWER TO CONTROL PANEL - Continued

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  142    143    144    145    146  147  148    149    150    151    152  
img
. .
TM 5-3825-270-23&P
0027
15-AMP
CIRCUIT BREAKER
INSIDE OF
TERMINAL 2
CONTROL PANEL
15-AMP
CIRCUIT BREAKER
TERMINAL 1
Figure 11. 15-amp Circuit Breaker Terminal 1 - Step 9.
3.
Connect black multimeter probe to known good ground.
4.
Note multimeter reading.
CONDITION/INDICATION
Are 22 to 28 VDC present at 15-amp circuit breaker terminal 1?
DECISION
No - Repair or replace clear wire from 15-amp circuit breaker, terminal 1 positive battery terminal. (WP 0099)
Verify problem is solved. (Step 11 - Does control panel have power?)
Yes - Go to step 10. (Step 10 - Are 22 to 28 VDC present at 15-amp circuit breaker terminal 2?)
STEP 10
Are 22 to 28 VDC present at 15-amp circuit breaker terminal 2?
WARNING
Remove all jewelry such as rings, ID tags, bracelets, etc., prior to working on or around
vehicle. Jewelry and tools can catch on equipment, contact positive electrical circuits, and
cause a direct short, severe burns, or electrical shock. Failure to comply may result in injury
or death to personnel.
1.
Ensure multimeter is setup to measure voltage.
2.
Connect red multimeter probe to 15-amp circuit breaker terminal 2.
15-AMP
CIRCUIT BREAKER
INSIDE OF
TERMINAL 2
CONTROL PANEL
15-AMP
CIRCUIT BREAKER
TERMINAL 1
Figure 12. 15-amp Circuit Breaker Terminal 2 - Step 10.
3.
Connect black multimeter probe to known good ground.
0027-10