TM 5-3825-270-23&P
0027
Table 1. Battery State Of Charge Voltage Table - Step 5 - Continued.
90%
12.6
25.2
80%
12.5
25
70%
12.3
24.6
60%
12.2
24.4
50%
12.1
24.2
40%
12.0
24
30%
11.8
23.6
20%
11.7
23.4
10%
11.6
23.2
0%
<=11.6
<=23.2
CONDITION/INDICATION
Do batteries read 24.2 to 25.4 volts with multimeter?
DECISION
No - Service (WP 0082), or replace batteries. (WP 0086) Verify problem is solved. (Step 11 - Does control panel
have power?)
Yes - Go to step 6. (Step 6 - Are 22 to 28 VDC present at emergency stop switch, terminal 1?)
STEP 6
Are 22 to 28 VDC present at emergency stop switch, terminal 1?
1.
Remove six control panel faceplate screws.
0027-5