TM 5-3825-270-23&P
FIELD MAINTENANCE
NO POWER TO CONTROL PANEL
INITIAL SETUP:
References (cont.)
Tools and Special Tools
Engine Off/Battery Drain Indicator Does Not
Tool Kit, General Mechanic's: Automotive
Field Level Preventive Maintenance Checks And
Tap & Die Set (Screwdriver) (WP 0225, Table 1,
Item 2)
Main Control Panel Emergency Stop Pushbutton
Personnel Required
Water Distributor Operator Manual (TM
Construction Equipment Repairer 91L (2)
5-3825-270-10)
References
Equipment Condition
Engine OFF. (TM 5-3825-270-10)
TROUBLESHOOTING PROCEDURE
NO POWER TO CONTROL PANEL
STEP 1
Is 15-amp circuit breaker tripped?
NOTE
The 15-amp circuit breaker works in conjunction with the emergency stop switch to control
power to the control panel. If a power surge is detected, the 15-amp circuit breaker will trip
prohibiting the emergency stop switch to supply power to the control panel and engine.
Verify 15-amp circuit breaker position.
15-AMP
CIRCUIT
BREAKER