NO POWER TO CONTROL PANEL
Figure 3. Batteries And Battery Terminals - Step 3.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  134    135    136    137    138  139  140    141    142    143    144  
img
. .
TM 5-3825-270-23&P
0027
CONDITION/INDICATION
Is 15-amp circuit breaker tripped?
DECISION
No - Go to step 2. (Step 2 - Does BATTERY VOLTAGE gauge read 22 to 28 VDC?)
Yes - Reset 15-amp circuit breaker. Verify problem is solved. (Step 11 - Does control panel have power?) If 15-
amp circuit breaker trips again after reset, do not attempt to reset. Notify maintenance personnel 15-amp circuit
breaker is tripped.
STEP 2
Does BATTERY VOLTAGE gauge read 22 to 28 VDC?
1.
Rotate EMERGENCY STOP switch to on position. (TM 5-3825-270-10)
2.
Observe BATTERY VOLTAGE gauge.
BATTERY
VOLTAGE GAUGE
Figure 2. Battery Voltage Gauge - Step 2.
CONDITION/INDICATION
Does BATTERY VOLTAGE gauge read 22 to 28 VDC?
DECISION
No - Go to step 3. (Step 3 - Are batteries properly connected?)
Yes - Control panel has power. Go to Engine Off/Battery Drain Indicator Does Not Illuminate. (WP 0031)
STEP 3
Are batteries properly connected?
1.
Open battery box cover. (TM 5-3825-270-10)
2.
Visually inspect batteries for proper connection.
0027-2