• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 2. Battery Voltage Gauge - Step 2.
Figure 5. Battery Terminals - Step 5.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  135    136    137    138    139  140  141    142    143    144    145  
img
. . .
TM 5-3825-270-23&P
0027
BATTERY
TERMINALS
BATTERIES
Figure 3. Batteries And Battery Terminals - Step 3.
CONDITION/INDICATION
Are batteries properly connected?
DECISION
No - Properly connect batteries. (WP 0085) Verify problem is solved. (Step 11 - Does control panel have
power?)
Yes - Go to step 4. (Step 4 - Are battery terminals corroded?)
STEP 4
Are battery terminals corroded?
Visually inspect battery terminals for corrosion.
BATTERY
TERMINALS
BATTERIES
Figure 4. Batteries And Battery Terminals - Step 4.
CONDITION/INDICATION
Are battery terminals corroded?
DECISION
No - Go to step 5. (Step 5 - Do batteries read 24.2 to 25.4 volts with multimeter?)
Yes - Clean battery terminals. (WP 0069) Verify problem is solved. (Step 11 - Does control panel have
power?)
0027-3


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.