Figure 4. Work Light Harness Connector Pin 2 - Step 4.
Figure 7. Light Switch - Step 6.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  128    129    130    131    132  133  134    135    136    137    138  
img
.
TM 5-3825-270-23&P
0025
CONTROL PANEL
FACEPLATE SCREWS
Figure 5. Control Panel Faceplate Screws - Step 5.
4.
Set multimeter to measure continuity.
CAUTION
Ensure electrical power is off prior to working on all electrical connections. Failure to comply
may result in damage to equipment.
5.
Place red multimeter probe to LIGHTS switch terminal 1.
TERMINAL 1
TERMINAL 2
BACK OF
CONTROL
PANEL
LIGHT
SWITCH
Figure 6. Light Switch - Step 5.
6.
Place black multimeter probe to LIGHTS switch terminal 2.
7.
While holding multimeter probes on terminals, place LIGHTS switch to ON position.
8.
Note multimeter reading.
CONDITION/INDICATION
Are less than 200 ohms measured across LIGHTS switch terminal 1 and terminal 2 with switch in ON position?