TM 5-3825-270-23&P
0025
CONTROL PANEL
FACEPLATE SCREWS
Figure 5. Control Panel Faceplate Screws - Step 5.
4.
CAUTION
Ensure electrical power is off prior to working on all electrical connections. Failure to comply
may result in damage to equipment.
5.
Place red multimeter probe to LIGHTS switch terminal 1.
TERMINAL 1
TERMINAL 2
BACK OF
CONTROL
PANEL
LIGHT
SWITCH
Figure 6. Light Switch - Step 5.
6.
Place black multimeter probe to LIGHTS switch terminal 2.
7.
While holding multimeter probes on terminals, place LIGHTS switch to ON position.
8.
Note multimeter reading.
CONDITION/INDICATION
Are less than 200 ohms measured across LIGHTS switch terminal 1 and terminal 2 with switch in ON position?