Figure 6. Starter Relay Wire Connections - Step 6.
Figure 8. Starter Motor Ground Wire - Step 8.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  22    23    24    25    26  27  28    29    30    31    32  
img
. . .
TM 5-3825-270-23&P
0006
STARTER SOLENOID
POSITIVE TERMINAL
Figure 7. Starter Solenoid Positive Terminal - Step 7.
3.
Connect black multimeter lead to a known good ground.
4.
Note multimeter reading.
CONDITION/INDICATION
Are 22 to 28 VDC present at starter solenoid positive terminal?
DECISION
No - Repair or replace red wire from battery positive terminal to starter solenoid positive terminal. (WP 0099)
Verify problem is solved. (Step 16 - Does engine crank?)
Yes - Go to step 8. (Step 8 - Are less than 200 ohms present from starter ground wire to a known good
ground?)
STEP 8
Are less than 200 ohms present from starter ground wire to a known good ground?
1.
Push in EMERGENCY STOP switch to off position. (TM 5-3825-270-10)
2.
Disconnect batteries. (WP 0085)
3.
Set multimeter to measure continuity.
WARNING
Ensure electrical power is off prior to working on all electrical systems. Failure to comply
may result in injury or death to personnel.
Remove all jewelry, such as rings, ID tags, bracelets, etc., prior to working on or around
equipment. Jewelry and tools can catch on equipment, contact positive electrical circuits,
and cause a direct short, severe burns, or electrical shock. Failure to comply may result
in injury or death to personnel.
4.
Connect red multimeter lead to starter ground wire.
0006-7