TM 5-3825-270-23&P
0006
STEP 3
Are battery cables properly connected and free of damage and corrosion?
1.
Push in EMERGENCY STOP switch to off position. (TM 5-3825-270-10)
2.
Open battery box cover. (TM 5-3825-270-10)
3.
Visually inspect battery cables and terminals for proper connection, damage, and corrosion. (WP 0085)
BATTERY
CABLES
BATTERIES
Figure 3. Battery Cables - Step 3.
CONDITION/INDICATION
Are battery cables properly connected and free of damage and corrosion?
DECISION
No - Clean and connect, or replace battery cables. (WP 0099) Verify problem is solved. (Step 16 - Does engine
crank?)
Yes - Go to step 4. (Step 4 - Do batteries measure 24.2 to 25.4 VDC with multimeter?)
STEP 4
Do batteries measure 24.2 to 25.4 VDC with multimeter?
WARNING
Remove all jewelry such as rings, ID tags, bracelets, etc., prior to working on or around
vehicle. Jewelry and tools can catch on equipment, contact positive electrical circuits, and
cause a direct short, severe burns, or electrical shock. Failure to comply may result in injury
or death to personnel.
1.
Set multimeter to measure voltage.
NOTE
Water distributor is equipped with two 12-volt batteries connected in series. Multimeter
measurements must be made from correct battery terminals to obtain 24-volt measurements.
2.
Connect red multimeter lead to positive battery terminal.
3.
Connect black multimeter lead to negative battery terminal.