TM 5-3825-270-23&P
0029
Table 1. Battery State Of Charge Voltage Table - Continued.
0%
<=11.6
<=23.2
CONDITION/INDICATION
Do batteries read 24.2 to 25.4 VDC with multimeter?
DECISION
No - Service (WP 0082) or replace batteries. (WP 0086) Verify problem is solved. (Step 7 - Does BATTERY
VOLTAGE gauge read normal?)
Yes - Go to step 4. (Step 4 - Are less than 200 ohms measured on red wire from BATTERY VOLTAGE gauge
harness connector pin, 6 to positive terminal strip, terminal 19?)
STEP 4
Are less than 200 ohms measured on red wire from BATTERY VOLTAGE gauge harness connector pin, 6 to
positive terminal strip, terminal 19?
NOTE
This test is checking for high resistance within a wire. High resistance may cause gauge
readings to read inaccurately or abnormally.
1.
Push in EMERGENCY STOP switch to off position. (TM 5-3825-270-10)
2.
3.
Remove six control panel faceplate screws.
CONTROL PANEL
FACEPLATE SCREWS
Figure 3. Control Panel Faceplate Screws - Step 4.