TM 5-3825-270-23&P
0029
WARNING
Ensure electrical power is off prior to working on all electrical systems. Failure to comply
may result in injury or death to personnel.
Remove all jewelry, such as rings, ID tags, bracelets, etc., prior to working on or around
equipment. Jewelry and tools can catch on equipment, contact positive electrical circuits,
and cause a direct short, severe burns, or electrical shock. Failure to comply may result
in injury or death to personnel.
4.
Disconnect harness connector from BATTERY VOLTAGE gauge. (WP 0087)
5.
6.
Connect red multimeter probe to BATTERY VOLTAGE gauge harness connector, pin 6.
GAUGE
HARNESS
CONNECTOR
1
2
3
4
5
6
BACK OF
CONTROL PANEL
Figure 4. Gauge Harness Connector - Step 4.
7.
Connect black multimeter probe to positive terminal strip, terminal 19.