Figure 14. Starter Solenoid White Wire - Step 11.
Figure 16. Engine Start/Engine Stop Switch Red Jumper Wires - Step 12.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  28    29    30    31    32  33  34    35    36    37    38  
img
.
TM 5-3825-270-23&P
0006
CONTROL PANEL
FACEPLATE SCREWS
Figure 15. Control Panel Faceplate Screws - Step 12.
3.
Set multimeter to measure continuity.
WARNING
Ensure electrical power is off prior to working on all electrical systems. Failure to comply
may result in injury or death to personnel.
Remove all jewelry, such as rings, ID tags, bracelets, etc., prior to working on or around
equipment. Jewelry and tools can catch on equipment, contact positive electrical circuits,
and cause a direct short, severe burns, or electrical shock. Failure to comply may result
in injury or death to personnel.
4.
Connect red multimeter lead to red jumper wires at ENGINE START/ENGINE STOP switch.