• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 20. Interconnect Terminal Strip - Step 14.
ENGINE DOES NOT CRANK - Continued

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  32    33    34    35    36  37  38    39    40    41    42  
img
. .
TM 5-3825-270-23&P
0006
CONDITION/INDICATION
Are less than 200 ohms present on black wire between interconnect terminal strip, terminal 6 and governor
controller harness connector pin G2?
DECISION
No - Repair or replace black wire between interconnect terminal strip, terminal 6 and governor controller harness
connector pin G2. (WP 0099) Verify problem is solved. (Step 16 - Does engine crank?)
Yes - Go to step 15. (Step 15 - Are less than 200 ohms present on blue wire from governor controller harness
connect pin A2 to starter relay?)
STEP 15
Are less than 200 ohms present on blue wire from governor controller harness connect pin A2 to starter
relay?
1.
Connect red multimeter lead to governor controller harness connector pin A2.
GOVERNOR
CONTROLLER
GOVERNOR
CONTROLLER
HARNESS
CONNECTOR
A
E
F
K
3
3
2
2
1
1
Figure 22. Governor Controller Harness Connector Pin A2 - Step 15.
2.
Connect black multimeter lead to blue wire at starter relay.
STARTER RELAY
BLUE WIRE
Figure 23. Starter Relay Blue Wire - Step 15.
0006-17