Figure 22. Emergency Stop Button.
Figure 24. Fuel Level.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  515    516    517    518    519  520  521    522    523    524    525  
img
.
TM 5-3820-276-10-2
0203
Table 2.
PMCS - Grouter - During Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
1
5
4
3
2
WWDS00574
Figure 23. Fault Indicators.
3. Check low oil pressure fault indicator (Figure 23,
LED status indicator on.
Item 2).
Notify maintenance.
4. Check engine high temperature fault indicator
LED status indicator on.
(Figure 23, Item 3).
Notify maintenance.
5. Check battery under voltage/battery over voltage
LED status indicator on.
fault indicator (Figure 23, Item 4).
Notify maintenance.
6. Check overspeed fault indicator (Figure 23, Item 5).
LED status indicator on.
Notify maintenance.
WARNING
2
During
Fuel Level
Fuel is highly flammable and can be
accidently ignited. Do not allow fuel to come
in contact with hot surfaces, such as
exhaust manifold, pipe, or muffler. Do not
smoke or allow open flame or sparks in the
vicinity while working on any part of fuel
system. Failure to comply may result in
injury or death to personnel. Seek medical
attention in the event of an injury.