TM 5-3820-276-10-2
0203
Table 3.
PMCS - Grouter - After Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
Check hydraulic oil level. Keep hydraulic oil level
Hydraulic oil is not visible
towards upper bold line (Figure 28, Item 1) but
in the sight glass.
between it and lower bold line (Figure 28, Item 2). Add
1
2
WWDS00575
Figure 28. Hydraulic Oil Sight Glass.
WARNING
3
After
Engine Oil Level
Do not allow hot oil or components to touch
your skin. Hot oil or components will burn
your skin. Wear heat-resistant gloves,
goggles, and protective clothing when you
work near hot oil or components. If hot oil
gets on your skin, seek medical aid
immediately. Failure to comply may result in
injury or death to personnel. Seek medical
attention in the event of an injury.
Check engine oil level on dipstick (Figure 29, Item 1).
Engine oil is above full
mark (Figure 29, Item 2).
Notify maintenance.
02/13/2013root(pmcswp)wpno(I20003)