Figure 24. Fuel Level.
Figure 27. Fuel Level.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  517    518    519    520    521  522  523    524    525    526    527  
img
.
TM 5-3820-276-10-2
0203
Table 2.
PMCS - Grouter - During Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
CAUTION
4
During
Hydraulic Oil
Temperature
Do not continue to run engine if hydraulic oil
temperature rises above specification.
Failure to comply may result in damage to
equipment.
Check hydraulic oil temperature gauge (Figure 26, Item Hydraulic oil exceeds
1). Hydraulic oil temperature must be between 125F
190F (88C). Notify
(52C) and 190F (88C).
maintenance.
1
WWDS00629
Figure 26. Hydraulic Oil Temperature Gauge.
Table 3.
PMCS - Grouter - After Drilling Equipment Operation.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
WARNING
1
After
Fuel Level
Fuel is highly flammable and can be
accidently ignited. Do not allow fuel to come
in contact with hot surfaces, such as
exhaust manifold, pipe, or muffler. Do not
smoke or allow open flame or sparks in the
vicinity while working on any part of fuel
system. Failure to comply may result in
injury or death to personnel. Seek medical
attention in the event of an injury.
0203-20
02/13/2013root(pmcswp)wpno(I20003)