TM 5-3820-276-10-2
0203
Table 1.
PMCS - Grouter - Before Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
WARNING
17
Before
Battery
DO NOT allow battery acid to contact eyes,
skin, or fabric. Upon contact with eyes or
skin, immediately flush with water, apply
first aid and obtain medical attention. DO
NOT lean over battery when connecting or
disconnecting battery cables. DO NOT
allow negative and positive cables to touch
each other. Keep open flame or sparks
away from battery vent holes. ALWAYS
wear eye protection when working with
batteries. Failure to comply may result in
injury or death to personnel. Seek medical
attention in the event of an injury.
Visually check terminals (Figure 17, Item 3), cables
Battery not secure,
(Figure 17, Item 1), and battery hold-down (Figure 17,
terminals loose or
Item 2) for security and signs of corrosion.
corroded, or cables
damaged. Notify
maintenance.
1
2
WWDS00561
3
Figure 17. Battery.
18
Before
Platform
1. Rotate latch (Figure 18, Item 1) and lower platform
(Figure 18, Item 3).
02/13/2013root(pmcswp)wpno(I20003)