DERRICK DOES NOT RAISE/LOWER PROPERLY - WWDR - Continued
ROD HANDLER DOES NOT OPERATE PROPERLY - WWDR - Continued

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  62    63    64    65    66  67  68    69    70    71    72  
img
.
TM 5-3820-276-10-2
0106
OPERATOR MAINTENANCE
ROD HANDLER DOES NOT OPERATE PROPERLY - WATER WELL DRILLING RIG (WWDR)
INITIAL SETUP:
References
Equipment Condition
Volume 1, WP 0024
Engine off (Volume 1, WP 0012)
Volume 1, WP 0025
TROUBLESHOOTING PROCEDURE
ROD HANDLER DOES NOT OPERATE PROPERLY - WWDR
SYMPTOM
Rod handler does not operate in automated mode.
MALFUNCTION
Rod not properly installed to drill rod handling arm.
CORRECTIVE ACTION
Verify if rod is installed properly to drill rod handling arm (Volume 1, WP 0025).
a.
If rod is not installed properly to drill rod handling arm, proceed to next MALFUNCTION -
Rod lifting beam not working properly.
b.
If rod is installed properly to drill rod handling arm, and automated or manual operation of
rod handler is not achievable, notify maintenance.