TRUCK MOUNTED AIR COMPRESSOR DOES NOT OPERATE PROPERLY - WATER WELL DRILLING RIG (WWDR)
NORMAL/RIG MODE P.T.O. DOES NOT ENGAGE - WWDR - Continued

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  65    66    67    68    69  70  71    72    73    74    75  
img
. .
TM 5-3820-276-10-2
0108
OPERATOR MAINTENANCE
NORMAL/RIG MODE POWER TAKE-OFF (P.T.O.) DOES NOT ENGAGE - WATER WELL DRILLING RIG
(WWDR)
INITIAL SETUP:
References
Equipment Condition
Volume 1, WP 0006
Engine off (Volume 1, WP 0012)
Volume 1, WP 0017
WP 0198
TROUBLESHOOTING PROCEDURE
NORMAL/RIG MODE P.T.O. DOES NOT ENGAGE - WWDR
SYMPTOM
P.T.O engaged light does not illuminate when attempting to engage P.T.O.
MALFUNCTION
Rig transmission not set properly.
CORRECTIVE ACTION
NOTE
Air pressure must be above 100 psi (689 kPa) before changing mode of
operation.
P.T.O MODE light should illuminate on dash when RIG MODE is
selected.
1.
Start engine (Volume 1, WP 0012).
2.
Set RIG MODE/ROAD MODE switch to RIG MODE position (Volume 1, WP 0017).
3.
Ensure transmission is in 9th gear (Volume 1, WP 0017).
a.
If P.T.O. engaged light illuminates, P.T.O. is engaged. Problem solved.
b.
If P.T.O. engaged light does not illuminate, proceed to next MALFUNCTION - Air leak
present.
0108-1
02/13/2013root(tswp)wpno(T10026)