TM 5-3825-270-23&P
0199
INSTALLATION - Continued
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
15.
Coat threads of pressure sending unit assembly (Figure 12, Item 3) with sealant.
3
4
7
6
5
Figure 12. Discharge Tube and Pipe Assembly Pump Outlet Hose Installation.
NOTE
Install pressure sending unit as noted prior to removal to ensure proper installation.
16.
Install pressure sending unit assembly (Figure 12, Item 3) on discharge tube (Figure 12, Item 4).
17.
Install water hose (Figure 12, Item 5) on fitting (Figure 12, Item 7) with clamp (Figure 12, Item 6).
18.
Connect connector (Figure 13, Item 2) to harness connector (Figure 13, Item 1).