Figure 8. Discharge Tube and Pipe Assembly Pump Outlet Hose Installation.
Figure 11. Discharge Tube and Pipe Assembly Pump Outlet Hose Installation.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  1084    1085    1086    1087    1088  1089  1090    1091    1092    1093    1094  
img
.
TM 5-3825-270-23&P
0199
INSTALLATION - Continued
5.
Install water hose (Figure 9, Item 24) on flange (Figure 9, Item 21) with two clamps (Figure 9, Item 17). Tighten
two clamps to 70 lb-in (8 Nm).
6.
Install flange (Figure 9, Item 21) on cross pipe (Figure 9, Item 20) with gasket (Figure 9, Item 22), eight screws
(Figure 9, Item 18) and locknuts (Figure 9, Item 19).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
7.
Coat threads of drain cock (Figure 10, Item 8) with sealant.
4
8
Figure 10. Discharge Tube and Pipe Assembly Pump Outlet Hose Installation.
8.
Install drain cock (Figure 10, Item 8) on discharge tube (Figure 10, Item 4).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
9.
Coat threads of fitting (Figure 11, Item 30) with sealant.