• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
3" VALVE REPLACEMENT
5" VALVE REPLACEMENT

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  875    876    877    878    879  880  881    882    883    884    885  
img
. .
TM 5-3825-270-23&P
0158
INSTALLATION
NOTE
All 3" valves are installed the same way. Valve V4 shown.
Some valves may have other components that have to be removed or supported during
valve replacement. Remove or support other components as necessary.
Install valve assembly as noted prior to removal.
1.
Install gasket (Figure 2, Item 1), valve (Figure 2, Item 2), gasket (Figure 2, Item 1), and adapter pipe (Figure
2, Item 6) on water tank assembly (Figure 2, Item 3) with eight screws (Figure 2, Item 5) and locknuts (Figure
2, Item 4).
1
2
3
4, 5
1
8
3
6
4
5
6
7
2
TIGHTENING SEQUENCE
Figure 2. 3" Valve Installation.
2.
Tighten locknuts (Figure 2, Item 4) in sequence shown.
END OF TASK
FOLLOW-ON MAINTENANCE
Install valve handle. (WP 0180)
END OF TASK
END OF WORK PACKAGE
0158-2


Privacy Statement
Press Release
Contact