TM 5-3825-270-23&P
0117
REMOVAL - Continued
8
9
6
7
14
13
12
10, 11
Figure 3. Injection Pump Removal.
4.
Remove plug (Figure 3, Item 12) from injection pump housing (Figure 3, Item 13).
5.
Remove bleeder valve (Figure 3, Item 6) from injection pump (Figure 3, Item 14).
NOTE
Note position of gaskets prior to removal to ensure proper installation.
6.
Remove screw (Figure 3, Item 10), fitting (Figure 3, Item 9), and two gaskets (Figure 3, Item 11) from injection
pump (Figure 3, Item 14). Discard gaskets.
CAUTION
Spring must not be allowed to retract into injection pump when removed from stud. Small
cable tie may be attached to end of spring to prevent losing spring. Failure to comply may
result in damage to equipment.
7.
Attach cable tie to spring (Figure 4, Item 19).