• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 4. Injection Pump Removal.
Figure 7. Injection Pump Removal.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  669    670    671    672    673  674  675    676    677    678    679  
img
.
TM 5-3825-270-23&P
0117
REMOVAL - Continued
14.
Remove shim (Figure 5, Item 22) from injection pump (Figure 5, Item 14). Discard shim.
END OF TASK
INSTALLATION
NOTE
Linkage must be aligned with grove in housing when installing injection pump.
1.
Position injection pump (Figure 6, Item 14) on injection pump housing (Figure 6, Item 13) with shim (Figure 6,
Item 22) and three screws (Figure 6, Item 21). Hand tighten screws.
20
21
13
22
14
Figure 6. Injection Pump Removal.
CAUTION
Ensure linkage is clear of injection pump while tightening screws. Failure to comply may result
in damage to equipment.
2.
Tighten three screws (Figure 6, Item 21) evenly until injection pump (Figure 6, Item 14) is evenly seated on
injection pump housing (Figure 6, Item 13).
3.
Install three nuts (Figure 6, Item 20) on injection pump (Figure 6, Item 14).
4.
Tighten screws (Figure 6, Item 21) to 17.33 to 20.22 lb ft (23.54 to 27.46 Nm).
5.
Tighten nuts (Figure 6, Item 20) to 20 lb ft (27 Nm).
6.
Position linkage (Figure 7, Item 16) on injection pump linkage (Figure 7, Item 17).