TM 5-3825-270-23&P
0117
INSTALLATION - Continued
15
17
16
CABLE TIE
19
18
Figure 7. Injection Pump Removal.
7.
Install locknut (Figure 7, Item 15) on stud (Figure 7, Item 18). Tighten locknut to 25 to 35 lb-in (3 to 4 Nm).
8.
Install spring (Figure 7, Item 19) on stud (Figure 7, Item 18).
9.
Remove cable tie from spring (Figure 7, Item 19).
10.
Install plug (Figure 8, Item 12) in injection pump housing (Figure 8, Item 13).
8
9
6
7
14
13
12
10, 11
Figure 8. Injection Pump Removal.
11.
Install fitting (Figure 8, Item 9) and two gaskets (Figure 8, Item 11) on injection pump (Figure 8, Item 14) with
screw (Figure 8, Item 10).