WATER LEVEL HIGH INDICATOR DOES NOT ILLUMINATE - Continued
Figure 2. Water Level Low Indicator - Step 1.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  260    261    262    263    264  265  266    267    268    269    270  
img
. . . . . . . . . .
TM 5-3825-270-23&P
0046
FIELD MAINTENANCE
MAIN CONTROL PANEL WATER LEVEL LOW INDICATOR DOES NOT ILLUMINATE
INITIAL SETUP:
References (cont.)
Tools and Special Tools
General Wire Harness Repair (WP 0099)
Tool Kit, General Mechanic's: Automotive
Low Tank Level Switch (WP 0189)
(WP 0225, Table 1, Item 12)
Main control Panel Tachometer Does Not
Multimeter (WP 0225, Table 1, Item 4)
Operate (WP 0037)
Tap & Die Set (Screwdriver) (WP 0225, Table 1,
Water Level Low Indicator Replacement
Item 2)
(WP 0104)
Water Distributor Operator Manual (TM
Personnel Required
5-3825-270-10)
Construction Equipment Repairer 91L (2)
Equipment Condition
References
Engine OFF. (TM 5-3825-270-10)
Dial Pointer Replacement (WP 0184)
TROUBLESHOOTING PROCEDURE
MAIN CONTROL PANEL WATER LEVEL LOW INDICATOR DOES NOT ILLUMINATE
STEP 1
Does WATER LEVEL LOW indicator illuminate with water level indicator magnet directly positioned over
low tank level switch?
1.
Open control panel cover. (TM 5-3825-270-10)
2.
Rotate EMERGENCY STOP switch to on position. (TM 5-3825-270-10)
3.
With the aid of an assistant, move water level indicator magnet directly over low tank level switch.
LOW TANK
LEVEL SWITCH
HIGH TANK
LEVEL
SWITCH
WATER LEVEL
INDICATOR
AND MAGNET
Figure 1. Water Level Indicator And Magnet - Step 1.
4.
Observe WATER LEVEL LOW indicator.