TM 5-3825-270-23&P
0045
CONDITION/INDICATION
Are less than 200 ohms measured on green/black wire from WATER LEVEL HIGH indicator to interconnect
terminal strip, terminal 11?
DECISION
No - Repair or replace green/black wire from interconnect terminal strip, terminal 11 to WATER LEVEL HIGH
indicator. (WP 0099) Verify problem is solved. (Step 8 - Does WATER LEVEL HIGH indicator illuminate?)
Yes - Repair or replace green wire from interconnect terminal strip, terminal 11 to high tank level switch harness
connector. (WP 0099) Verify problem is solved. (Step 8 - Does WATER LEVEL HIGH indicator illuminate?)
STEP 8
Does WATER LEVEL HIGH indicator illuminate?
1.
If disconnected, connect batteries. (WP 0085)
2.
Rotate EMERGENCY STOP switch to on position. (TM 5-3825-270-10)
3.
With the aid of an assistant, move water level indicator magnet directly over high tank level switch.
LOW TANK
LEVEL SWITCH
HIGH TANK
LEVEL
SWITCH
WATER LEVEL
INDICATOR
AND MAGNET
Figure 15. Water Level Indicator And Magnet - Step 8.
4.
Observe WATER LEVEL HIGH indicator.
WATER LEVEL
HIGH INDICATOR
Figure 16. WATER LEVEL HIGH Indicator - Step 8.