• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 4. Water Level High Indicator - Step 2.
Figure 7. Water Level Indicator And Magnet - Step 4.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  253    254    255    256    257  258  259    260    261    262    263  
img
. . . . . .
TM 5-3825-270-23&P
0045
CONDITION/INDICATION
Does tachometer operate?
DECISION
No - Go to Main Control Panel Tachometer Does Not Operate. (WP 0037) Verify problem is solved. (Step 8 -
Does WATER LEVEL HIGH indicator illuminate?)
Yes - Repair or replace black wire from tachometer to WATER LEVEL LOW indicator. (WP 0099) Verify problem
is solved. (Step 8 - Does WATER LEVEL HIGH indicator illuminate?)
STEP 4
Does WATER LEVEL HIGH indicator illuminate after swapping with WATER LEVEL LOW indicator?
1.
Push in EMERGENCY STOP switch to off position. (TM 5-3825-270-10)
2.
Remove six control panel faceplate screws.
CONTROL PANEL
FACEPLATE SCREWS
Figure 6. Control Panel Faceplate Screws - Step 4.
3.
Remove WATER LEVEL HIGH indicator. (WP 0103)
4.
Remove WATER LEVEL LOW indicator. (WP 0104)
5.
Install WATER LEVEL LOW indicator where WATER LEVEL HIGH indicator was removed. (WP 0103)
6.
Rotate EMERGENCY STOP switch to on position. (TM 5-3825-270-10)
7.
With the aid of an assistant, move water level indicator magnet directly over high tank level switch.
0045-4