TM 5-3825-270-23&P
0045
INSIDE OF
15-AMP
CONTROL PANEL
CIRCUIT BREAKER
20
1
1
15
5
5
EMERGENCY
10
10
10
STOP SWITCH
5
15
15
1
20
20
INTERCONNECT
POSITIVE
NEGATIVE
TERMINAL STRIP
TERMINAL STRIP
TERMINAL STRIP
Figure 9. Positive Terminal Strip - Step 5.
4.
With the aid of an assistant using jumper wire, connect black multimeter probe to pin 1 (white wire) at high tank
level switch harness connector.
PIN 1
PIN 2
(WHITE WIRE)
(GREEN WIRE)
Figure 10. High Tank Level Switch Harness Connector - Step 5.
5.
CONDITION/INDICATION
Are less than 200 ohms measured on white wire from positive terminal strip, terminal 16 to high tank level switch?
DECISION
No - Repair or replace white wire from positive terminal strip, terminal 16 to high tank level switch harness
connector. (WP 0099) Verify problem is solved. (Step 8 - Does WATER LEVEL HIGH indicator illuminate?)
Yes - Go to step 6. (Step 6 - Are less than 200 ohms measured on green wire from high tank level switch harness
connector, to green/black wire at WATER LEVEL HIGH indicator?)