• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 11. Water Level High Indicator - Step 6.
Figure 15. Water Level Indicator And Magnet - Step 8.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  257    258    259    260    261  262  263    264    265    266    267  
img
. .
TM 5-3825-270-23&P
0045
DECISION
No - Go to step 7. (Step 7 - Are less than 200 ohms measured on green/black wire from WATER LEVEL HIGH
indicator to interconnect terminal strip, terminal 11?)
Yes - Replace high tank level switch. (WP 0187) Verify problem is solved. (Step 8 - Does WATER LEVEL HIGH
indicator illuminate?)
STEP 7
Are less than 200 ohms measured on green/black wire from WATER LEVEL HIGH indicator to interconnect
terminal strip, terminal 11?
1.
Ensure multimeter is set to measure continuity.
2.
Connect red multimeter probe to green/black wire at WATER LEVEL HIGH indicator.
BLACK
BACK OF
WIRE
CONTROL
PANEL
WATER LEVEL
HIGH LIGHT
GREEN / BLACK
WIRE
Figure 13. Water Level High Indicator - Step 7.
3.
Connect black multimeter probe to white wire at interconnect terminal strip, terminal 11.
INSIDE OF
15-AMP
CONTROL PANEL
CIRCUIT BREAKER
20
1
1
15
5
5
EMERGENCY
10
10
10
STOP SWITCH
5
15
15
1
20
20
POSITIVE
NEGATIVE
INTERCONNECT
TERMINAL STRIP
TERMINAL STRIP
TERMINAL STRIP
Figure 14. Interconnect Terminal Strip - Step 7.
4.
Note multimeter reading.
0045-8


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.