Figure 7. Engine Resume/Idle Switch - Step 4.
Figure 9. Engine Resume/Idle Switch - Step 5.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  216    217    218    219    220  221  222    223    224    225    226  
img
. . .
TM 5-3825-270-23&P
0040
ENGINE
START/ENGINE
STOP SWITCH
ORANGE/RED
WIRE
RED
JUMPER
WIRES
ORANGE/BLACK
WIRE
Figure 8. Engine Start/Engine Stop Switch - Step 4.
4.
Note multimeter reading.
CONDITION/INDICATION
Are less than 200 ohms measured on red jumper wire between engine RESUME/IDLE switch and ENGINE
START switch?
DECISION
No - Repair or replace red jumper wire between engine RESUME/IDLE switch and ENGINE START/ENGINE
STOP switch. (WP 0099) Verify problem is solved. (Step 7 - Does engine RESUME/IDLE switch operate
normally?)
Yes - Replace governor controller. (WP 0092) Verify problem is solved. (Step 7 - Does engine RESUME/IDLE
switch operate normally?)
STEP 5
Are less than 200 ohms measured from black/red wire on engine RESUME/IDLE switch to interconnect
terminal strip, terminal 2?
1.
Ensure multimeter is set to measure continuity.
2.
Connect red multimeter probe to black/red wire on engine RESUME/IDLE switch.