Figure 5. Engine Resume/Idle Switch - Step 3.
Figure 8. Engine Start/Engine Stop Switch - Step 4.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  215    216    217    218    219  220  221    222    223    224    225  
img
.
TM 5-3825-270-23&P
0040
CONDITION/INDICATION
Are less than 200 ohms measured from red/black wire on engine RESUME/IDLE switch to governor controller
harness connector pin C3?
DECISION
No - Go to step 6. (Step 6 - Are less than 200 ohms measured from red/black wire on engine RESUME/IDLE
switch to interconnect terminal strip, terminal 3?)
Yes - Go to step 4. (Step 4 - Are less than 200 ohms measured on red jumper wire between engine RESUME/
IDLE switch and ENGINE START switch?)
STEP 4
Are less than 200 ohms measured on red jumper wire between engine RESUME/IDLE switch and ENGINE
START switch?
1.
Ensure multimeter is set to measure continuity.
2.
Connect red multimeter probe to red jumper wire at engine RESUME/IDLE switch.
BACK OF
RED/BLACK
PANEL
WIRE
ENGINE
RESUME/IDLE
SWITCH
RED
WIRE
BLACK/RED
WIRE
Figure 7. Engine Resume/Idle Switch - Step 4.
3.
Connect black multimeter probe to red jumper wire at ENGINE START/ENGINE STOP switch.