TM 5-3825-270-23&P
FIELD MAINTENANCE
ENGINE WILL NOT INCREASE RPM
INITIAL SETUP:
References (cont.)
Tools and Special Tools
Tool Kit, General Mechanic's: Automotive
Governor Control Module Replacement
Tap & Die Set (Screwdriver) (WP 0225, Table 1,
Governor Actuator Module Replacement
Item 2)
Field Level Preventive Maintenance Checks And
Personnel Required
Construction Equipment Repairer 91L (2)
Water Distributor Operator Manual (TM
5-3825-270-10)
References
Equipment Condition
Open/Close Engine Access Cover (TM
Engine OFF. (TM 5-3825-270-10)
5-3825-270-10)
Main Control Panel Engine Speed RPM Switch
TROUBLESHOOTING PROCEDURE
ENGINE WILL NOT INCREASE RPM
STEP 1
Is problem with engine speed present when using main control panel?
1.
Start engine. (TM 5-3825-270-10)
2.
Using main control panel, attempt to increase engine speed with engine speed RPM switch. (TM
5-3825-270-10)
ENGINE SPEED
RPM SWITCH
Figure 1. Engine Speed RPM Switch - Step 1.
3.
Observe engine performance.
4.
Shutdown engine. (TM 5-3825-270-10)