Figure 2. Governor Actuator Removal.
OIL SAMPLING VALVE REPLACEMENT

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  764    765    766    767    768  769  770    771    772    773    774  
img
. .
TM 5-3825-270-23&P
0133
INSTALLATION - Continued
2.
Install governor actuator (Figure 4, Item 3) on injection pump (Figure 4, Item 4) with two hex screws (Figure
4, Item 5).
3
4
5
Figure 4. Governor Actuator Installation.
3.
Connect connector (Figure 5, Item 2) to connector (Figure 5, Item 1).
1
2
1
Figure 5. Governor Actuator Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install rear access panel. (TM 5-3825-270-10)
2.
Connect batteries. (WP 0085)
END OF TASK
END OF WORK PACKAGE
0133-3/4 blank