TM 5-3825-270-23&P
0084
REMOVAL - Continued
23
24
Figure 5. Battery Box Wiring Removal.
CAUTION
Do not allow control panel to hang by wires. Failure to comply may result in damage to
equipment.
6.
Remove six screws (Figure 6, Item 25) and washers (Figure 6, Item 26) from main control box (Figure 6, Item
27) and control panel (Figure 6, Item 28).
25, 26
27
28
Figure 6. Battery Box Wiring Removal.
7.
Disconnect clear wire (Figure 7, Item 31) from 15 amp breaker (Figure 7, Item 32).