Figure 3. Water Tank Sump - Test 3.
CONDITION/INDICATION
Is water tank sump restricted?
DECISION
No - Problem not found and may have been missed or overlooked. Repeat all previous steps in this
troubleshooting procedure. Go to step 1. (Step 1 - Is gravity bar weldment damaged?) If problem still exists
after all troubleshooting test have been performed, notify supervisor.
Yes - Remove restriction or replace water tank. (WP 0195) Verify problem is solved. (Step 4 - Is gravity bar
weldment stream normal?)
STEP 4
Is gravity bar weldment stream normal?
Operate gravity bar weldment. (TM 5-3825-270-10)
CONDITION/INDICATION
Is gravity bar weldment stream normal?
DECISION
No - If the problem still exists, it is possible that another fault exists or that another troubleshooting procedure
applies. If this was the first time through the task, restart the same symptom troubleshooting fault task.
Yes - Problem solved. Restore water distributor to original operating condition.