TM 5-3825-270-23&P
0051
WATER
TANK SUMP
Figure 3. Water Tank Sump - Test 3.
CONDITION/INDICATION
Is water tank sump free of restriction?
DECISION
No - Remove restriction or replace water tank. Verify problem is solved. (Step 4 - Does gravity bar weldment
operate?)
Yes - Problem not found and may have been missed or overlooked. Repeat all previous steps in this
troubleshooting procedure. Go to step 1. (Step 1 - Is gravity bar weldment free of damage?) If problem still
exists after all troubleshooting test have been performed, notify supervisor.
STEP 4
Does gravity bar weldment operate?
Operate gravity bar weldment. (TM 5-3825-270-10)
CONDITION/INDICATION
Does gravity bar weldment operate?
DECISION
No - If the problem still exists, it is possible that another fault exists or that another troubleshooting procedure
applies. If this was the first time through the task, restart the same symptom troubleshooting fault task.
Yes - Problem solved. Restore water distributor to original operating condition.
END OF WORK PACKAGE