GRAVITY BAR WELDMENT STREAM LOW
Figure 3. Water Tank Sump - Test 3.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  290    291    292    293    294  295  296    297    298    299    300  
img
. .
TM 5-3825-270-23&P
0052
VALVE V2
CLOSURE
CAP C2
Figure 2. Closure Cap C2 - Step 2.
2.
Open valve V2. (TM 5-3825-270-10)
3.
Verify if water stream is normal at closure cap C2.
4.
Close valve V2 and install closure cap C2. (TM 5-3825-270-10)
CONDITION/INDICATION
Is water stream normal at closure cap C2 when valve V2 is opened?
DECISION
No - Go to step 3. (Step 3 - Is water tank sump restricted?)
Yes - Replace valve V8. (WP 0180) Verify problem is solved. (Step 4 - Is gravity bar weldment stream
normal?)
STEP 3
Is water tank sump restricted?
1.
Drain water tank. (TM 5-3825-270-10)
2.
Visually inspect water tank sump for restriction.
0052-2