GRAVITY BAR WELDMENT DOES NOT OPERATE
Figure 3. Water Tank Sump - Test 3.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  287    288    289    290    291  292  293    294    295    296    297  
img
. .
TM 5-3825-270-23&P
0051
VALVE V2
CLOSURE
CAP C2
Figure 2. Closure Cap C2 - Step 2.
2.
Open valve V2. (TM 5-3825-270-10)
3.
Verify if water is present at closure cap C2.
4.
Close valve V2 and install closure cap C2. (TM 5-3825-270-10)
CONDITION/INDICATION
Is water present at closure cap C2 when valve V2 is opened?
DECISION
No - Go to step 3. (Step 3 - Is water tank sump free of restriction?)
Yes - Replace valve V8. (WP 0180) Verify problem is solved. (Step 4 - Does gravity bar weldment operate?)
STEP 3
Is water tank sump free of restriction?
1.
Drain water tank. (TM 5-3825-270-10)
2.
Open manhole cover. (TM 5-3825-270-10)
3.
Visually inspect water tank sump for restriction.
0051-2