MANUAL WATER TURRET PRESSURE LOW
Figure 3. Valve V5 - Step 3.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  283    284    285    286    287  288  289    290    291    292    293  
img
. . .
TM 5-3825-270-23&P
0050
Does valve V6 open and close completely?
1.
Remove manual water turret. (WP 0163)
2.
Visually inspect valve V6 while opening and closing valve to ensure it opens and closes completely.
VALVE
V6
Figure 2. Valve V6 - Step 2.
CONDITION/INDICATION
Does valve V6 open and close completely?
DECISION
No - Replace valve V6. (WP 0180) Verify problem is solved. (Step 5 - Does manual water turret operate?)
Yes - Go to step 3. (Step 3 - Is valve V5 completely closed?)
STEP 3
Is valve V5 completely closed?
Verify valve V5 position.
0050-2