MANUAL WATER TURRET DOES NOT OPERATE
MANUAL WATER TURRET PRESSURE LOW

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  281    282    283    284    285  286  287    288    289    290    291  
img
. . . .
TM 5-3825-270-23&P
0049
STEP 2
Does water hose operate?
Operate water distributor water hose. (TM 5-3825-270-10)
CONDITION/INDICATION
Does water hose operate?
DECISION
No - Go to Water Pump Does Not Operate. (WP 0022)
Yes - Go to step 3. (Step 3 - Does WATER PUMP OUTLET gauge read normal?)
STEP 3
Does WATER PUMP OUTLET gauge read normal?
1.
Start engine. (TM 5-3825-270-10)
2.
Observe WATER PUMP OUTLET gauge.
WATER PUMP
OUTLET GAUGE
Figure 2. Water Pump Outlet Gauge - Step 3.
CONDITION/INDICATION
Does WATER PUMP OUTLET gauge read normal?
DECISION
No - Go to Water Pressure Erratic. (WP 0023)
Yes - Replace valve V6. (WP 0180) Verify problem is solved. (Step 4 - Does manual water turret operate?)
STEP 4
Does manual water turret operate?
Operate manual water turret. (TM 5-3825-270-10)
CONDITION/INDICATION
Does manual water turret operate?
DECISION
No - If the problem still exists, it is possible that another fault exists or that another troubleshooting procedure
applies. If this was the first time through the task, restart the same symptom troubleshooting fault task.
Yes - Problem solved. Restore water distributor to original operating condition.
END OF WORK PACKAGE