• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 3. Left And Right Solenoid Valves - Step 4.
WATER SPRINKLER HEAD PRESSURE LOW

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  296    297    298    299    300  301  302    303    304    305    306  
img
. . .
TM 5-3825-270-23&P
0053
STEP 7
Are air hoses and fittings free of leaks and damage?
1.
Remove air valve cover plate. (WP 0164)
2.
Visually inspect air hoses and fittings for leaks and damage.
SOLENOID
VALVES
AIR
HOSES
Figure 4. Air Hoses - Step 7.
CONDITION/INDICATION
Are air hoses and fittings free of leaks and damage?
DECISION
No - Replace damaged or leaking air hoses and/or fittings. Verify problem is solved. (Step 8 - Do water sprinklers
operate?)
Yes - Replace air line lubricator. (WP 0169) Verify problem is solved. (Step 8 - Do water sprinklers operate?)
STEP 8
Do water sprinklers operate?
Operate water sprinklers. (TM 5-3825-270-10)
CONDITION/INDICATION
Do water sprinklers operate?
DECISION
No - If the problem still exists, it is possible that another fault exists or that another troubleshooting procedure
applies. If this was the first time through the task, restart the same symptom troubleshooting fault task.
Yes - Problem solved. Restore water distributor to original operating condition.
END OF WORK PACKAGE
0053-5/6 blank