COMPRESSOR FAILS TO LOAD WHEN SERVICE AIR SWITCH IS PRESSED - PORTABLE AIR COMPRESSOR (PAC)
ENGINE HAS HIGH TEMPERATURE - PORTABLE AIR COMPRESSOR (PAC)

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  308    309    310    311    312  313  314    315    316    317    318  
img
. .
TM 5-3820-276-10-2
0184
COMPRESSOR FAILS TO LOAD WHEN SERVICE AIR SWITCH IS PRESSED - PAC - Continued
MALFUNCTION
Engine rpm too low for compressor operation.
CORRECTIVE ACTION
NOTE
Following a successful engine start, engine rpm will accelerate to 1,200 rpm
initially, then 1,600 rpm for warm-up.
1.
Visually inspect ENGINE SPEED gauge and verify engine is running at 1,200 rpm or greater
(Figure 1).
ENGINE
SPEED
GAUGE
WWDS00254
Figure 1.
Engine Speed Gauge.
2.
Shut down engine (Volume 1, WP 0059).
a.
If engine speed is less than 1,200 rpm, proceed to Engine RPM Low troubleshooting
procedure (WP 0190).
b.
If engine speed is 1,200 rpm or greater but compressor continues to not start, notify
maintenance.
END OF WORK PACKAGE
0184-2
02/13/2013root(tswp)wpno(T30009)