Figure 1. Engine Speed Gauge
ENGINE RPM LOW - PAC - Continued

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  326    327    328    329    330  331  332    333    334    335    336  
img
. . . . . . .
TM 5-3820-276-10-2
0190
OPERATOR MAINTENANCE
ENGINE RPM LOW - PORTABLE AIR COMPRESSOR (PAC)
INITIAL SETUP:
References
Equipment Condition
WP 0177
Engine off (Volume 1, WP 0059)
WP 0178
WP 0214
TROUBLESHOOTING PROCEDURE
ENGINE RPM LOW - PAC
SYMPTOM
Engine rpm less than 1,200 rpm during warm-up or normal operation.
MALFUNCTION
Air filter(s) dirty or restricted.
CORRECTIVE ACTION
Verify if air filters (Figure 1) are dirty or restricted (WP 0214).
AIR
FILTERS
WWDS00270
Figure 1.
Air Filters.
a.
If dirty, clean air filter(s) (WP 0214). Start engine and verify engine rpm returns to normal
(Volume 1, WP 0059).
b.
If restricted, remove restriction. Start engine and verify engine rpm returns to normal
(Volume 1, WP 0059).
c.
If air filters are not dirty or restricted, proceed to next Malfunction - Engine fault code
present.
0190-1