COMPRESSOR UNIT HAS LOW CFM - PAC - Continued
MALFUNCTION
Air leak(s) present.
CORRECTIVE ACTION
WARNING
Do not use hands or other body parts to check for air leaks. High pressure air
can cut through skin and high temperature air can burn skin. Failure to comply
may result in injury or death to personnel. Seek medical attention in the event of
an injury.
Check for air leaks throughout PAC unit and any attached components.
a.
If air leak is present at one or more fittings, tighten fitting. Start engine and verify if proper
compressor operation is restored. If problem persists, or leak is due to damaged hose or
other component, notify maintenance.
b.
If no air leak is found, proceed to next Malfunction - Compressor fault code present.
MALFUNCTION
Compressor fault code present.
CORRECTIVE ACTION
a.
If compressor fault code(s) are present, follow instructions given in compressor fault code
b.
If compressor fault code(s) are not present, notify maintenance.
END OF WORK PACKAGE